• TEL: 0086-13083697781

how to calculate quantity of binding wires for steel bars

Get Price

We can supply you need how to calculate quantity of binding wires for steel bars.

Bar Bending Schedule for footings |Estimation of

Aug 13, 2017 · Remember, Steel required for construction is ordered in Kgs or Number of Bars. The standard size of each bar is 12m. The final output of BBS calculation is in Kgs or in Number of 12m Bars. To make it easier calculation is divided into two parts, X bar Calculations and Y bar calculations. Calculate the weight of Steel TMT Rods in Bundle Shyam SteelTMT Bar Size (In mm) TMT Bar weight in kg/m:Shyam Steel flexiSTRONG TMT Bar 5.5 mm:0.186:Shyam Steel flexiSTRONG TMT Bar 6 mm:0.222:Shyam Steel flexiSTRONG TMT Bar 8 mm:0.395:Shyam Steel flexiSTRONG TMT Bar 10 mm:0.617:Shyam Steel flexiSTRONG TMT Bar 12 mm:0.890:Shyam Steel flexiSTRONG TMT Bar 16 mm:1.580:Shyam Steel flexiSTRONG

Civil Engineering Service

HOW TO CALCULATE QUANTITY OF BINDING WIRES FOR STEEL BARS Binding wires are used to tie the steel bars. Besides estimating of steel quantity for different members it is also important to know the required amount of binding wires. So that we can order correct quantity of steel. Civil Engineering ServiceHOW TO CALCULATE QUANTITY OF BINDING WIRES FOR STEEL BARS Binding wires are used to tie the steel bars. Besides estimating of steel quantity for different members it is also important to know the required amount of binding wires. So that we can order correct quantity of steel. ESSENTIAL TECHNICAL DATA ON STEEL REINFORCEMENTREO CALCULATOR for steel reinforcement area calculations. REO WIRE GAUGE for measuring REOMESH® wire diameters. REO BAR GAUGE for measuring REBAR diameters. NATIONAL PRODUCT & SERVICES CATALOGUE A comprehensive guide to reinforcing products, services and solutions. REINFORCING.COM the online resource for products, technical

Estimating calculation - SlideShare

Nov 29, 2015 · Ground Beam as Stirrups Material Cost 8mm diameter mild steel bar delivered to site = RM1000.00/tonne Allow labour unloading and stacking = RM5.00/tonne Tie wire = (0.66kg / 100kg) x 1000 x (RM4.00 x 1.06) = RM27.98/tonne Spacer for rebar = RM4.00/tonne 7% wastage = RM1000.00 x 0.70 = RM700.00/tonne Rolling margin = RM22.00/tonne Cost of How To Calculate Quantity Of Binding Wire For Steel The Binding wire calculation does not have any formula to find out the weight of binding wire, so here we just use the Thumb rules to find the weight of binding wire. 1- Binding Wire are required for 100 kg of steel = 0.9 to 1.3 kg. 2- Binding wire are required for 1 Ton ( 1000 kg) of steel = 9 to 13 kg. 3- For one Ton steel work ( 1000 kg) if the diameter of steel is 28 mm to 32 mm so there we required just 7 kg of How To Calculate Quantity Of Binding Wire For Steel Works The Binding wire calculation does not have any formula to find out the weight of binding wire, so here we just use the Thumb rules to find the weight of binding wire. 1- Binding Wire are required for 100 kg of steel = 0.9 to 1.3 kg 2- Binding wire are required for 1 Ton (1000 kg) of steel = 9 to 13 kg

How to Calculate Quantity of Binding wire for steel

In this Video Lecture today I will teach That How to Calculate Quantity of Binding wire for steel. Articles Civil. Share; You might like. Post a Comment. Post a Comment. Previous Post Next Post Follow Us. Popular Posts. Bamboo is the Best Alternative to Steel Reinforcement. How to Calculate the Weight of Steel Bar? - Online CalculatorIts hard to find the exact weight of steel bars according to its area, it is advisable to refer the manufacturers chart to calculate the weight of the steel bar. If you cant find the details, then the below steel bar weight calculation formulas are useful for site level execution. Metal Weight Calculator - steel weight calculator Metal weight calculator online - free steel weight calculator. Has pre-entered densities for dozens of commonly-used metals and metal alloys like steel, aluminum, nickel, iron, copper, cadmium, gold, silver, etc. Calculate the weight of a steel beam, bar, tube, profiles, channels, or a simple metal sheet.

PLACING AND TYING REINFORCING STEEL

Tie wire is used to hold rebar in place to ensure that when concrete is placed the bars do not shift out of position. Sixteen gauge wire is used to tie. Table 7-6.-Multishearing. reinforcing bars. About 12 pounds (5.4 kg) of wire is required to tie an average ton (0.9 tome) of bars. NOTE:Tie wire adds nothing to the strength of the steel. PLACING AND TYING REINFORCING STEELTie wire is used to hold rebar in place to ensure that when concrete is placed the bars do not shift out of position. Sixteen gauge wire is used to tie. Table 7-6.-Multishearing. reinforcing bars. About 12 pounds (5.4 kg) of wire is required to tie an average ton (0.9 tome) of bars. NOTE:Tie wire adds nothing to the strength of the steel. Reinforcement Binding Wire Binding Wire Used In - SkpBased on the previous experience and thumb rules, the quantity of binding wire can be determined. It is generally found that per 1000 kg (1 Ton), the amount of binding wire is 9 to 13 kg. As per industry practice, the quantity of binding wire fluctuates from 7 to 13 kg per 1000 kg (1 tonne) of steel.

Things Site Engineers Must Know About Reinforcement

In steel reinforcement binding wire required is 8 kg per MT. Lapping is not allowed for the bars having diameters more than 36 mm. Minimum number of bars for a square column are 4 and for circular column are 6. Longitudinal reinforcement should not be less than 0.8% and more than 6% of gross C/S. Thumb Rules used in the Construction by Civil EngineeringDec 14, 2018 · Battens Quantity Calculation:Shuttering batten usually have a length & width of 75mm x 40mm. Batten Quantity = 19.82 x No. of Ply Sheets. if the construction requires 25 Ply sheets, the total quantity of Battens are 19.82 x 25 = 495 Battens . Nails & Binding Wire Quantity in Shuttering:75gms of Nails are used for 1m 2 of Shuttering. 75gms of Binding wire is consumed for every 1m 2 of Thumb Rules used in the Construction by Civil EngineeringDec 14, 2018 · Thumb rule to calculate Steel quantity of above slab = Volume of Concrete x Density of Steel x % of Steel of Member Steel quantity required for above slab = 3 x 7850 x 0.01 = 235Kgs For accurate calculation, you can refer to Bar Bending Schedule Thumb rule to calculate the Shuttering area:

How To Calculate Quantity Of Binding Wire For Steel Works

Dec 06, 2018 · 1- Binding Wire are required for 100 kg of steel = 0.9 to 1.3 kg. 2- Binding wire is required for 1 Ton ( 1000 kg) of steel = 9 to 13 kg. 3- For one Ton steelwork ( 1000 kg) if the diameter of steel is 28 mm to 32 mm so there we required just 7 kg of binding wire to bend the steel with each other. So there are the important for find the weight of binding wire for RCC (steel) works which are exact weight for above steel weight. The quantity of binding wire depends on. 1-

Get Price

We can supply you need how to calculate quantity of binding wires for steel bars.